AUTOMATIC BACK FLUSHING FILTER

F61 Auto Back Flushing Filter

Auto Back Flushing Filter

Description

EDM can improve the overall efficiency of 10% to 30%.
 

System Operation

  • Two minutes silent operation of back flushing, there will be no interference with current job.
  • Customizable, provides multi EDM use.
  • Easy maintenance, just check and empty the dust bag at times. It is recommended to replace the core-filters after 10000~12500 hours.

Machine Specifications

 
Electrical SpecificationsFilterable ParticlesUNIT(Fixed / Mobile) F61 / F61M F37 / F37M F19 / F19M
Number of Core-Filters PCS 61 37 19
Pressure bar 6 6 -
Filter Bucket Capacity L 175 100 150
Layout mm (W x D) 720 x 1350 720 x 1350 610 x 890
Filter Lifespan hr 20000 20000 10000
Filter Flow L/sec 4 2.5 1.25
Filter Period hr 8 4 -
Time of flushing within Filter Period sec 120 100 -
Filterable Particles μm 1 1 1
Electrical Specifications KVA 220V or 380V / 3Ø 2KVA 220V or 380V / 3Ø 2KVA -
 
Specification are subject to change without prior notice due to continual research and development.